Cool Automation 9000H Instalační příručka

Procházejte online nebo si stáhněte Instalační příručka pro ne Cool Automation 9000H. Cool Automation 9000H Installation guide Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - Installation Guide

9000 Series SensorInstallation GuideYour Guide to Permanent9000 Series Sensor InstallationRockwell Automation EntekP/N 48204

Strany 2 - Copyright Notice

2 Entek 9000 Series Sensor Installation Guide9000 Series SensorsModel NumberPart NoBiasOutputSensitivity Description NotesGeneral Purpose9000A 43781I

Strany 3 - Table of Contents

9000 Series SensorsEntek 9000 Series Sensor Installation Guide 39200FM 43789I 8–12 VDC 100 mV/g General purpose, precision low profile ring style acce

Strany 4 - Table of Contents

4 Entek 9000 Series Sensor Installation Guide9000 Series SensorsHigh Temperature9100T 43805I 8–14 VDC 100 mV/g High temperature accelerometerTop exit,

Strany 5 - Terms and Conditions

Sensor MountingEntek 9000 Series Sensor Installation Guide 5Sensor MountingNext to choosing the correct sensor, the sensor mounting is the most import

Strany 6

6 Entek 9000 Series Sensor Installation GuideSensor MountingFollow the specific sensor’s guidelines for the dimensions of the hole, the type of set sc

Strany 7

Sensor MountingEntek 9000 Series Sensor Installation Guide 7When connecting cables for sensors with ground-isolated cases, make sure that the cable sh

Strany 8

8 Entek 9000 Series Sensor Installation GuideSensor MountingMounting sensors with a bracketSometimes a sensor will not fit at the desired location on

Strany 9 - 9000 Series

Sensor Cable GuidelinesEntek 9000 Series Sensor Installation Guide 9Sensor Cable GuidelinesThis section describes some common cable guidelines to get

Strany 10

10 Entek 9000 Series Sensor Installation GuideSensor Cable GuidelinesCable InstallationThe cable from the sensor is a critical component in getting th

Strany 11

Sensor Cable GuidelinesEntek 9000 Series Sensor Installation Guide 11Cable lengthThe nomograph below provides a simple, graphical method for obtaining

Strany 12

Copyright NoticeCopyright © 2003 by Entek IRD International CorporationAll Rights ReservedSecond Edition 2003Printed in the U.S.A.This Manual is suppl

Strany 13 - Sensor Mounting

12 Entek 9000 Series Sensor Installation GuideSensor Cable GuidelinesFor example, when running a 100ft. cable with a capacitance of 30 pF/ft, the tota

Strany 14

Sensor Cable GuidelinesEntek 9000 Series Sensor Installation Guide 13For a sensor with a top exit cable connection, make sure there is at least 6 inch

Strany 15

14 Entek 9000 Series Sensor Installation GuideSensor Cable GuidelinesSplicing cablesSplices in cables are acceptable if the connections are soldered.

Strany 16 - Machine housing

Connecting 9000 Series Sensors to MonitorsEntek 9000 Series Sensor Installation Guide 15Connecting 9000 Series Sensors to MonitorsThis following drawi

Strany 17 - Sensor Cable Guidelines

16 Entek 9000 Series Sensor Installation GuideConnecting 9000 Series Sensors to MonitorsCommonChannel A SignalPin A - SignalPin B - CommonCable shield

Strany 18 - Cable Installation

Connecting 9000 Series Sensors to MonitorsEntek 9000 Series Sensor Installation Guide 17 1618192423202122177101511121314982645314344484546473242353841

Strany 19 - Frequency (Hz)

18 Entek 9000 Series Sensor Installation GuideConnecting 9000 Series Sensors to MonitorsA - BNetwork Input RJ-45 JackStatus LED'sRS-232DB-9 (fema

Strany 20

Connecting 9000 Series Sensors to MonitorsEntek 9000 Series Sensor Installation Guide 19CONNECTING 9000 SERIES SENSORS TO XM-120/121/122 VIBRATION MO

Strany 21 - Cable construction

20 Entek 9000 Series Sensor Installation GuideConnecting 9000 Series Sensors to MonitorsTYPICAL WIRING FOR IEPE ACCELEROMETER TO XM-120/121/122 VIBRAT

Strany 22 - Conduit boxes

Entek 9000 Series Sensor Installation Guide 3Index Index5800 monitors 156600 monitors 15Aadhesive mounting 7attenuation, signal in cable 10BBelden nu

Strany 23

Entek 9000 Series Sensor Installation Guide iiiContents Table of ContentsIntroduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strany 24

4 Entek 9000 Series Sensor Installation GuideIndexSsensorsconnections 9general purpose 2high frequency 3high temperature 4low frequency 3mounting 5mou

Strany 25 - Pin B - Common

iv Entek 9000 Series Sensor Installation GuideTable of Contents

Strany 26 - Terminal 2 - Ground

Terms and ConditionsEntek 9000 Series Sensor Installation Guide vENTEK IRD INTERNATIONAL CORPORATION GENERAL TERMS AND CONDITIONS1. CONTRACT. When Cus

Strany 27

Terms and Conditionsvi Entek 9000 Series Sensor Installation Guide6. CUSTOMER RESPONSIBILITIES. Customer shall be solely responsible for the accuracy

Strany 28

Terms and ConditionsEntek 9000 Series Sensor Installation Guide vii9. EXCLUSIVE REMEDIES AND LIABILITY LIMITATION. THE REMEDIES PROVIDED HEREIN ARE CU

Strany 29

Terms and Conditionsviii Entek 9000 Series Sensor Installation Guide

Strany 30

Entek 9000 Series Sensor Installation Guide 19000 Series1. 9000 Series Sensor InstallationThis manual shows you how to install the 9000 series sensors

Komentáře k této Příručce